Size and weight information


ITEM\MODEL
2815AC
2820AC
3515AC
3520AC
3525AC
4120AC
4125AC
4130AC
4825AC
4832AC
4840AC
L
54.2
54.2
59
59
59
72.6
72.6
72.6
81.6
81.6
81.6
W
38
38
45
45
45
55.6
55.6
55.6
63.6
63.6
63.6
H
34.2
34.2
39.1
39.1
39.1
43.5
43.5
43.5
51.6
52.5
53.2
WEIGHT
125g
150g
170g
200g
230g
260g
310g
370g
440g
530g
650g

 

Typical Model List for CCC Adaptors

Table 1 (From 2815AC to 4120AC)

No.

Output
AC Voltage

Output AC Current(mA)
2815AC

2820AC

3515AC

3520AC

3525AC

4120AC
1  24V

10-50

20-70

50-120

50-190

100-250

150-300

2
23V

10-55

20-80

50-140

50-210

100-270

150-320

3 22V/21V

10-60

20-90

50-160

50-230

150-300

180-350

4 20V

10-70

20-110

50-190

50-270

150-350

200-400

5
19V

10-80

20-120

50-200

80-290

150-370

200-430

6 18V/17V

10-90

20-130

50-210

80-310

180-400

220-450

7 16V

10-110

20-150

50-240

80-350

180-450

250-500

8 15V

10-120

20-160

50-270

80-370

200-480

300-550

9 14V/13V

10-130

20-170

50-300

100-400

250-500

350-600

10 12V

10-150

20-200

100-350

150-460

250-600

400-700

11 11V

10-160

20-230

100-380

150-500

300-700

450-800

12 10V

10-180

20-260

100-420

150-550

300-800

500-900

13 9V

10-200

20-290

100-450

200-600

350-900

600-1000

14 8V

10-230

20-330

100-500

200-650

350-1000

650-1100

15 7V

10-250

20-370

150-580

200-750

450-1200

750-1300

16
6V

10-300

20-430

150-650

250-850

500-1300

800-1400

17 5V

10-350

20-500

150-750

250-1000

600-1400

900-1600

18 4V

10-450

20-600

200-900

300-1200

800-1600

1200-2000

19 3.5V

10-500

20-700

250-1000

300-1300

900-1800

1300-2200

20 3V

10-550

20-800

250-1150

400-1400

1000-2000

1400-2500

21
2.4V

10-700

20-950

250-1300

400-1600

1000-2300

1400-2800

22 2.0-1.2V            

Typical Model List for CCC adaptors

Table 2 (From 4125AC to 4840AC)

No.

Output
AC Voltage

Output AC Current(mA)

4125AC

4130AC

4825AC

4832AC

4840AC
1  24V

100-400

200-500

150-600

300-800

600-1000

2
23V

100-420

200-550

200-650

350-850

600-1000

3 22V/21V

100-450

200-600

300-700

450-900

800-1200

4 20V

100-500

200-700

350-800

500-1000

1000-1400

5
19V

150-530

250-750

400-850

550-1050

1000-1400

6 18V/17V

150-570

300-800

500-900

650-1100

1100-1600

7 16V

150-650

350-900

500-1000

700-1300

1200-1800

8 15V

150-700

400-950

500-1050

750-1400

1300-1900

9 14V/13V

200-750

500-1000

600-1100

850-1500

1500-2100

10 12V

200-850

550-1100

650-1300

900-1700

1500-2500

11 11V

250-950

600-1200

700-1400

950-1800

1500-2700

12 10V

250-1050

700-1300

750-1500

1000-1900

1500-3000

13 9V

300-1150

800-1400

800-1600

1100-2000

1600-3300

14 8V

300-1300

900-1500

850-1800

1100-2200

1700-3600

15 7V

400-1400

1100-1700

950-2000

1300-2500

2000-4000

16
6V

400-1600

1200-1900

1000-2300

1400-2800

2000-4500

17 5V

500-1800

1300-2100

1000-2600

1500-3200

2000-5000

18 4V

700-2200

1500-2500

1000-3000

1700-3800

 
19 3.5V

700-2500

1600-2800

1000-3200

1800-4200

 
20 3V

800-2700

1800-3100

1000-3500

1900-4600

 
21
2.4V

800-3000

2000-3500

1000-4000

2000-5000

 
22 2.0-1.2V          


Product Highlight

Built-in Features and Protections
  • A thermal fuse of nonresettable type located within the primary circuit
Hipot Test and Insulation Resistance
  • 2000VAC (leakage current 5mA) for 1 minute between AC plug and DC plug and Case;
  • Or 3000KVAC (leakage current 5mA)for 2 seconds.
  • 500VDC 10M Ohms min. between AC plug and DC plug and case
Cord Relief Bending
  • The cord can withstand weight of 200g,swinging from left to right at 120 angle degrees, 40 cycle/min 1000 times min.
Drop Test and Life Test
  • For model 2815AC,2820AC,3515AC,3520AC,3525AC dropped from a height of 120cm onto a dry wood surface,with 1 cm thickness, no abnormal condition happen.
  • For model 4120AC,4125AC,4130AC,dropped from a height of 90cm onto a dry wood surface, with 1 cm thickness, no abnormal condition happen.
  • For model 4825AC,4832AC,4840AC,dropped from a height of 80cm onto a dry wood surface,with 1 cm thickness, no abnormal condition happen.
Life Test
  • In an ambient temperature of 25 degree C +/- 5 Degree C, 95% RH applied to power source of rated input to primary with secondary full load for 8 hours continuously test, It should meet the requirement.
Safey Approvals
  • GB8898 & GB4943

 


All the rights reserved for Wintach Electronics Co., Limited